3 Calibration Procedures
74 Keysight E3633A and E3634A Service Guide
To unsecure the power supply for calibration
The power supply can use a calibration security code to prevent unauthorized or
accidental calibration. This procedure shows you how to unsecure the power
supply for calibration from the front panel.
1 Turn on the front-panel calibration mode.
Turn on the calibration mode by holding down (Calibrate) key as you turn
on the power supply and hold down the key until you hear a long beep.
If the power supply is secured, you will see the above message from the front
panel for approximately one second. The “CAL MODE” message is then
displayed on the front panel.
2 Move to the security code by pressing (Secure) key.
3 Enter the security code using the knob and resolution selection keys.
The security code is set to “HP003633”
[1]
or “HP003634”
[2]
when the power
supply is shipped from the factory. The security code is stored in non-volatile
memory and does not change when the power has been off or after a remote
interface reset.
To enter the security code from the front panel, enter only the last six
digits.
To enter the security code from the remote interface, you may enter up to
12 characters.
SECURED
000000 CODE
003633 CODE (E3633A)
003634 CODE (E3634A)
[1] For Keysight E3633A Model
[2] For Keysight E3634A Model

Table of Contents

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the Keysight Technologies E3633A and is the answer not in the manual?

Keysight Technologies E3633A Specifications

General IconGeneral
BrandKeysight Technologies
ModelE3633A
CategoryPower Supply
LanguageEnglish

Related product manuals