EasyManua.ls Logo

Keysight Technologies EL30000 Series - Configuring the Input Turn-On;Turn-Off Sequence

Keysight Technologies EL30000 Series
141 pages
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Loading...
Configuring the Input Turn-On/Turn-Off Sequence
Turn-on and turn-off delays control the turn-on and turn-off timing of the inputs in relation to each other.
Step 1 Set the input voltage, current, power or resistance of the input channels:
Refer to steps 1 and 2 under Controlling the Inputs and set the input values of all inputs that will be sequenced.
Step 2 Configure the turn-on turn-off delays:
Press Input Settings to access the Input Settings On/Off Delays. Enter the On Delays and Off Delays for all inputs
that will participate in the input on/off delay sequence. Values can range from 0 to 1023 seconds.
Step 3 Coupling selected inputs:
This step is only required if you will be including some inputs to participate in an input on/off delay sequence
or if you are coupling multiple electronic loads. If only a single input is to be used in the sequence, you can
skip this step.
From the menu, press On/Off Coupling to access the On/Off Coupling mode settings.
Press Coup CH 1 to toggle between Off and On in order to turn off or on the coupling for Input 1.
Press Coup CH 2 to toggle between Off and On in order to turn off or on the coupling for Input 2. (applicable
for EL34243A only)
Step 4 Use the All Inputs On and Off keys:
Once input delays have been set, press [All On/Off] to start the On delay and Off delay sequence.
Keysight EL30000 Series User's Guide 71