279
Chapter 5 Error Messages
Execution Errors
4
5
-221 Settings conflict;
PWM turned off by selection of other mode or modulation
The function generator will allow only one modulation, sweep, or burst
mode to be enabled at the same time. When you enable a modulation,
sweep, or burst mode, all other modes are turned off.
-221 Settings conflict;
sweep turned off by selection of other mode or modulation
The function generator will allow only one modulation, sweep, or burst
mode to be enabled at the same time. When you enable a modulation,
sweep, or burst mode, all other modes are turned off.
-221 Settings conflict;
not able to modulate this function
The function generator cannot generate an AM or FM modulated
waveform using the ramp, pulse, noise, dc voltage, or arbitrary waveform
functions.
-221 Settings conflict;
PWM available in only pulse function
The function generator cannot generate a PWM modulated waveform
using any function other than pulse.
-221 Settings conflict;
not able to sweep this function
The function generator cannot generate a sweep using the pulse, noise,
dc voltage, or arbitrary waveform functions.
-221 Settings conflict;
not able to burst this function
The function generator cannot generate a burst using the pulse, noise, dc
voltage, or arbitrary waveform functions.
-221 Settings conflict;
not able to modulate noise, modulation turned off
The function generator cannot generate a modulated waveform using the
noise function. The selected modulation mode has been turned off.
33210A users guide.book Page 279 Wednesday, July 16, 2008 11:16 AM