EasyManua.ls Logo

Keysight 33210A - Page 287

Keysight 33210A
351 pages
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Loading...
285
Chapter 5 Error Messages
Execution Errors
4
5
-221 Settings conflict;
amplitude changed due to offset
The relationship between output amplitude
and offset voltage is shown
below. Vmax is the maximum peak voltage for the selected output
termination (5 volts for a 50 load or 10 volts for a high-impedance load).
If the existing amplitude is not valid, the function generator will
automatically adjust it to the maximum value allowed with the offset
voltage specified.
Vpp <
2 X (Vmax |Voffset|)
-221 Settings conflict;
low level changed due to high level
You can set the levels to a positive or negative value, but note that the
high level must always be greater than the low level. If you specify a high
level that is less than the existing low level, the function generator will
automatically set the low level to be 1 mV less than the high level.
-221 Settings conflict;
high level changed due to low level
You can set the levels to a positive or negative value, but note that the
high level must always be greater than the low level. If you specify a low
level that is greater than the existing high level, the function generator
will automatically set the high level to be 1 mV greater than the low
level.
-222 Data out of range;
value clipped to upper limit
The specified parameter is outside of the function generator’s capability.
The function generator has adjusted the parameter to the maximum
value allowed. Example: PHAS 1000
-222 Data out of range;
value clipped to lower limit
The specified parameter is outside of the function generator’s capability.
The function generator has adjusted the parameter to the minimum
value allowed. Example: PHAS -1000
33210A users guide.book Page 285 Wednesday, July 16, 2008 11:16 AM