3 Operations and Features
36 Keysight U8001A/U8002A User’s and Service Guide
Memory Operations
For Keysight U8001A/U8002A single output DC power supplies, up to three
operating states can be stored in non-volatile storage locations. The storage
feature remembers the voltage and current limit value settings, OVP
[1]
/OCP
[2]
On/Off states, and OVP/OCP trip levels. The following steps show you how to
store and recall an operating state.
Storing Operating State
1 Press on the “Memory” button.
The M1 annunciator will blink.
2 Turn the knob to choose the memory location for storing the operation
state.
The M1, M2 and M3 annunciators will blink in a round-robin manner.
3 Press on the “Memory” button again to save the operating state in the
chosen memory.
Display will show “donE”.
The M1, M2 and M3 annunciators will be turned off.
[1] OVP- over voltage protection
[2] OCP- over current protection
NOTE
To cancel the operation, allow the unit to idle for five seconds.