Sirius Capacitor Module User Manual Model Number - 3550-48-B-1.7C-M-SD-A-G
This manual is subject to change without notice and at the sole discretion of Kilowatt Labs, Inc.
Kilowatt Labs, Inc. | www.kilowattlabs.com
29
System Configuration
Measurement Calibration
Manual/Auto Data Logging\Module firmware updating
Internal SD card reading/refreshing
Statistical Analyzing/ Graphical result
10. Shelf Life:
Shelf life is the life of the Module in years from the date it is manufactured to the time it is first
operated. The shelf life of supercapacitor cell is 10 years.
11. Maintenance:
The Sirius Module does not require periodic maintenance.
12. Disposal:
Dispose according to local regulation.
13. Test Procedures:
13.1 Round Trip Efficiency Test:
Round Trip efficiency test is performed to evaluate the performance of the Module. There are three
factors to be considered in the design of the test cycle for round trip efficiency.
How to charge and discharge the Sirius Module.
At what voltage to start and end the charge/discharge?
At which points to do the measurement.
Considering the efficiency and cost involved in the production line, we used constant current load test
method for Round trip efficiency characterization.
Test Equipment:
DC Charger test system or any other test system which can be used to charge and discharge
Module with test cycle programing. We used WRL48V80A27cd DC Charger Motor for charging and
WRL-FDY48L20 Battery Discharge Tester for discharging.
Test Temperature:
Room temperature 23
o
C ±2
o
C.
Temperature controlled chamber can be used if testing at any environment other than room
temperature.
Test Current: