Sirius Capacitor Module – User Manual Model Number - 3550-48-B-1.7C-M-SD-A-G
This manual is subject to change without notice and at the sole discretion of Kilowatt Labs, Inc.
Kilowatt Labs, Inc. | www.kilowattlabs.com
30
• Different current within the maximum limit specified by the test equipment manufacturer can be
applied to the test.
• We took test currents in the range of 20-70A with current steps of 10.
Test Process:
Step 1: Rest (open circuit):
• Record test time, test current, and voltage at the start of the test (t1, I1, V1).
Step 2: Charge Cycle:
• Charge voltage to its maximum voltage.
• Record test time, test current, voltage and total charge energy at the end of charge cycle (t2, I2,
V2, E1).
Step 3: Discharge Cycle:
• Discharge Module to its minimum voltage.
• Record test time, test current, voltage and total discharge energy at the end of discharge cycle (t3,
I3, V3, E2).
Step 4: Round Trip Efficiency Calculation:
13.2 Performance Data: