Kinetico Premier Plus Water Softener Installation and User Manual
6
Contents of box
Identify the following parts before proceeding.
Meter Disc A B C D E F G H I * J * K * L * M *
PPM 207 221 238 256 279 305 337 376 426 456 490 531 578 635 686 770 878 1020
˚f 21 22 24 26 28 30 34 38 43 46 49 53 58 64 69 77 88 102
˚D 12 12 13 14 16 17 19 21 24 26 27 30 32 36 38 43 49 57
Litres between
regenerations
1583 1480 1377 1274 1171 1068 965 862 759 708 656 605 553 502 450 399 347 224
Cabinet dimensions (h x w x d) 645 x 480 x 396 mm
Salt used per regeneration 0.56 kg
Regeneration time 11 minutes
Flow rate @ 1 bar pressure drop 22.7 l/min
Pipe connections - in/out ¾” BSP
Min/max operating pressure 1.8 - 6 bar
Min/max operating temperature 2 - 49˚C
Specifications
Max
hardness
1 x in/out retaining
bracket and pin
4 x o-ring
1 x 2cc silicone tube 2 x 3/4” washers
2 x 3/4” BSP in/out adaptor
By-pass valve
(included with the Premier Plus HE ALT BP only)