Kinetico Premier Plus Water Softener Installation and User Manual
14
Review
By-pass assembly:
Ensure the assembly is in the
“by-pass” position.
5
Pressure:
If a pressure regulating valve
has been fitted, ensure it has been
correctly set to 6 bar maximum.
1
Drain line:
Ensure the drain line is securely
attached, has no restrictions or kinks,
uses an airgap and is fully compliant.
2
Overflow:
Ensure the overflow has no kinks, is
securely attached and that water is
able to fall away with gravity.
3
Inlet/Outlet connections:
Ensure the hoses/plumbing are
attached securely, using the washers
provided, and are firmly held in place
using the retaining bracket and pin.
4
Service PositionBy-pass Position
Run drain line:
a: Run a drain line to a
discharge point, checking for
any obstructions or possible
kinks.
FOLLOW LOCAL PLUMBING
CODES.
b: Push the drain line onto the
barbed fitting and tighten the
jubilee clip securely.
6
Please note:
Drain lines must not run more than
2.4m up or exceed a total of 9m. The
drain line must not be restricted or
kinked.
✗