Chapter 1 Before Use 1-7
1. 4. 2 Scanner (KIP 860)
Subject Specification
Scanning method Contact Image Sensor (CIS)
(5 pieces of A4 sized CIS)
Light source LED (R/G/B)
Scanning speed
(600 dpi, normal quality)
(max)
Monochrome : 65mm/s
Grayscale : 65mm/s
Color : 22mm/s
NOTE : speed can vary dependent on scan software.
Setting of original Face up
Starting point of scan Center
Scan width Max: 914.4mm / 36”
Min : 210mm
Scan length Max: 6m / 19.7ft (Including the margin area)
Min : 210mm / 8.5” (Including the margin area)
NOTE :
If the print is longer than 6m, its image quality or the reliability of paper feeding is not
guaranteed.
Optical resolution 600dpi
Digital resolution 200 / 300 / 400 / 600 dpi
Original transportation Single sheet by device transportation
Transportable original
thickness
Max: 1.60mm
Min : 0.05mm
NOTE :
Suggest to change “It does not guarantee both scan/copy image quality and original feeding
reliability in case the original is non-standard size one of which thickness is 0.25mm or thicker.
NOTE