8
Operation of the generator at an altitude lower than the
carburetor is jetted for may result in reduced performance,
overheating, and serious engine damage caused by an
excessively lean air/fuel mixture.
3.5 Ambient Temperature
Generator output generally declines 1% for every 1F (5.5° C) above 85° F (29° C).
The normal operating range of the generator is -20° to 113° F (-29° to 45° C).
Do not operate the generator when the ambient
temperature is below -20° F (-29°)
Do not operate the generator when the ambient
temperature is above 113° F (45° C)