EasyManua.ls Logo

Kipor IG6000 - Page 19

Kipor IG6000
52 pages
Print Icon
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Loading...
17
Disconnect the two 6P input connectors
on the inverter unit. (6p for single
voltage , 4p or 2p for double voltage)
Disconnect spark plug cap or igniter
connector, measure the AC voltage of
main winding and sub. Winding when the
stator motor is running. Measure one AC
voltage of main winding or sub. Winding
for double voltage unit.
Black black: 30V
White white: 1V
Single voltage230/240V type:
Black black: 60V
White white: 1V
Single voltage 120V type:
Black black: 30V
White white:
1V
→abnormal
1. Check the wiring of the stator leads in
the harness. Repair or replace the
harness.
2. Rotor internal magnetic weaken,
replace the rotor.
↓normal (255 volts)
Replace inverter unit
i. No AC output
Is the engine speed normal?
abnormal
Perform the throttle control system
troubleshooting
↓normal
Check AC receptacles
→abnormal
Replace receptacles2.7.9
↓normal
Check the rectifier
→abnormal
Replace the rectifier
↓normal
Measure the resistance between two
blue wire on the rectifier
Resistance:0.03~0.04Ω
→abnormal
Check and repair the wire harness or
replace the stator
↓normal
Rotor losses excitation, replace the rotor
j. Electric starter doesn’t run.
Check the battery voltage
abnormal
Replace the battery
↓normal
Check ignition switch
→abnormal
Replace the ignition switch
↓normal
Check the battery switch
→abnormal
Replace battery switch( sucking coil)
↓normal
Check the starting motor
→abnormal
Replace the starting motor
↓normal
Check and repair or replace main wire
harness

Other manuals for Kipor IG6000