EasyManua.ls Logo

Kirisun DM588 - Page 36

Kirisun DM588
151 pages
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Loading...
DM588 Service Manual
Item Environment
Measurement Tool and Method
Index Requirement
Test Device Test Point Tool Method
12. Narrow-Band
RSSI 5
1) Set the tester to RX
state;
2) RF Gen Freq =
debugging frequency;
3) Set Amplitude =
-80dBm:
AFGen1 Freq: 1kHz;
FM:1.5kHz
1) Run the debugging software on
the PC, and set the tester to
adjustment mode;
2) Double click [Narrow-Band RSSI
5], and click [Low Frequency];
3) Click Start. When the value
become stable, click Stop;
3) Repeat the above steps on
medium and high frequencies
respectively.
13. Wide-Band
RSSI 1
1) Set the tester to RX
state;
2) Set RF Gen Freq =
debugging frequency, and
Amplitude = -120dBm
AFGen1 Freq: 1kHz;
FM:1.5kHz
General-purpose
tester
Connect
antenna
interface of the
radio to RF
IN/OUT
interface of the
tester
PC
1) Run the debugging software on
the PC, and set the tester to
adjustment mode;
2) Double click [Wide-Band RSSI 1],
and click [Low Frequency];
3) Click Start. When the value
become stable, click Stop;
3) Repeat the above steps on
medium and high frequencies
respectively.
33