DM588 Service Manual
Item Environment
Measurement Tool and Method
Index Requirement
Test Device Test Point Tool Method
12. Narrow-Band
RSSI 5
1) Set the tester to RX
state;
2) RF Gen Freq =
debugging frequency;
3) Set Amplitude =
-80dBm:
AFGen1 Freq: 1kHz;
FM:1.5kHz
1) Run the debugging software on
the PC, and set the tester to
adjustment mode;
2) Double click [Narrow-Band RSSI
5], and click [Low Frequency];
3) Click Start. When the value
become stable, click Stop;
3) Repeat the above steps on
medium and high frequencies
13. Wide-Band
RSSI 1
1) Set the tester to RX
state;
2) Set RF Gen Freq =
debugging frequency, and
Amplitude = -120dBm
AFGen1 Freq: 1kHz;
FM:1.5kHz
General-purpose
tester
Connect
antenna
interface of the
radio to RF
IN/OUT
interface of the
tester
PC
1) Run the debugging software on
the PC, and set the tester to
adjustment mode;
2) Double click [Wide-Band RSSI 1],
and click [Low Frequency];
3) Click Start. When the value
become stable, click Stop;
3) Repeat the above steps on
medium and high frequencies
respectively.
33