DM588 Service Manual
Item Environment
Measurement Tool and Method
Index Requirement
Test Device Test Point Tool Method
18. RX BER
1) Power on the radio and
disable TX. Connect the
RF IN interface of the
radio to the RF OUT
interface of the tester
using a standard adapter
and a HF cable.
2) Set the tester to DMR
mode, set Transmit to the
receiving frequency, Lvl:
-119dBm, and select “STD
AEROFLEX 3920
Connect
antenna
interface of the
radio to RF IN
interface
1) Run the debugging software on
the PC, and set the tester to
adjustment mode;
2) Double click [RX BER], and click
[Low Frequency];
3) Observe the BER value on the
PC;
4) Switch to medium and high
frequencies respectively, and repeat
the above steps.
For -119dBm, BER
is < 5%
36