6. Wait until the warning limit is exceeded and the buzzer
sounds.
ð
The Display alternates between the current temperature
and the two error messages (upper and lower tempera-
ture alarm).
7. Turn unit key to position “1”.
ð
The test function is completed, the electronic delay is
switched on again.
The Display displays the current temperature of the
chilled goods.
The test function is ended automatically
after 10 minutes.
8.
After the check, clean and disinfect the unit
Ä
Chapter 8
“Cleaning and disinfection” on page 56.
Remove the dust from the condenser (Fig. 6) at least every six
months in order to avoid affecting the performance of the cooling
machine.
Requirement:
n The back of the unit is accessible.
1. Dust off the condenser (for example with a brush or vacuum
cleaner).
2. Check the condenser for visible damage and wear.
Document the following results of the tests:
n Date of performance
n Results of the individual tests
n Other test results
The owner is obliged to keep the documenta-
tion of the safety inspection at least until the
next inspection.
Checking the condenser
Documenting test results
Maintenance
Safety inspection
18.12.2018 Refrigerator/freezer BL series 61