2-2
Fire Hazard
Do not use grill near combustible
materials.
Do not store combustible materials
near grill.
Doing so can result in death or re.
Explosion Hazard
Do not store fuel tank in a garage or
indoors.
Do not store grill with fuel tank in a
garage or indoors.
Failure to follow these instructions can
result in death, explosion, or re.
Location Requirements
Select a location that provides minimum ex-
posure to wind and trafc paths. The location
should be away from strong draft areas.
Do not obstruct ow of combustion and ven-
tilation air.
Clearance to combustible construction for built-
in and freestanding outdoor grills:
• A minimum of 24" (58 cm) must be maintained
between the grill hood, sides and back and
any combustible construction.
• A 24" (58 cm) minimum clearance must also
be maintained below the cooking surface and
any combustible construction.
Rotisserie (u models only)
A 6" (15.2 cm) minimum clearance is needed
for the rotisserie motor.
A grounded, 3-prong outlet located to the left
of the grill is required. See “Electrical Require-
ments” section.
Rotisserie (accessory)(s models only)
If you equip your grill with a rotisserie, a 6"
(15.2 cm) minimum clearance is needed for
the rotisserie motor.
A grounded, 3-prong outlet located to the left
of the grill is required. See “Electrical Require-
ments” section.
Product Dimensions
Style 1 - Freestanding Outdoor Grill
(s models only)