2-13
If Converted to Natural Gas
Explosion Hazard
Use a new CSA International approved
“outdoor”gas supply line.
Securely tighten all gas connections.
Failure to do so can result in death, ex-
plosion, or re.
WARNING
This installation must conform with local codes
and ordinances.
In the absence of local codes, installations must
conform with either the National Fuel Gas Code
ANSI Z223.1, or CAN/CGAB149.1 Natural Gas
and Propane installation code.
Copies of the standards listed above may be
obtained from:
CSA International
8501 East Pleasant Valley Rd.
Cleveland, Ohio 44131-5575
National Fire Protection Association
One Batterymarch Park
Quincy, Massachusetts 02269
1. Make gas connections.
A combination of pipe ttings must be
used to connect the grill to the existing
gas line.
If local codes permit, use an outdoor
flexible stainless steel tubing gas
connector, design-certified by CSA
International, to connect the grill to the
rigid gas supply line. A 5/8" diameter
line is recommended. Using a wrench
to tighten, connect the gas supply to
the grill.
Use pipe-joint compound on all non-
ared male threads. Do not kink or
damage the exible connector when
moving the grill.
A. Grill gas pipe
B. New ANSI Z21.54 certied gray hose
C. Rear of grill
D. To Natural gas supply
A
B
C
D
†®TEFLON is a registered trademark of E.I. Du Pont
De Nemours and Company.
2. Open the manual shutoff valve in the gas
supply line. The valve is open when the
handle is parallel to the gas pipe.
A. Closed valve
B. Open valve
A
B
3. Test all connections by brushing on an
approved noncorrosive leak-detection
solution. Bubbles will show a leak. Correct
any leak found.
4. The igniter battery is not factory installed. A
1.5 volt “D” size alkaline battery is located
in the accessory box on the grill grate.
Install battery at this time following the
instructions in the “Replacing the Igniter
Battery” section. (s models only)
5. Go to “Check and Adjust the Burners”
section.
Pipe-joint compounds suitable for use
with Natural gas must be used. Do not
use TEFLON®† tape.