EasyManua.ls Logo

Kiturami WORLD PLUS-13D - Piping for Upper Floor

Default Icon
42 pages
Print Icon
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Loading...
2-4-1 Standard pipework
※ Caution on piping
This boiler is equipped with the pressure controller of water-inlet to protect
the body and each valves from the instantaneous high-water-pressure
when or closing the water valves.
This pressure controller of water-inlet works under 2.5kgf/㎠ of inlet water
pipe pressure. Therefore, if over it, should install the pressure reducing
valve for inlet water pipe additionally.
If over pressure of inlet water, it may cause bursting pipes of house or
boiler inside and stopping hot water from boiler.
2-4 pipework
Boiler Cool water
INLET
Pressure reducing valve
Cool water
valve join
Gas filter
strainer
Nitrogen tank
Heating pipe
Distributor
Cold water inlet pipe
Hot water supply pipe
Bath
FCU or Radiator
Cold water valve
Pressure redncing valve
Gas inlet pipe
17페이지