4
OTHER MEASUREMENT APPLICATIONS
Maximum Input: 600V AC RMS or 600V DC
• Diode Test: Approx. 1mA, open circuit voltage ~3.0V DC
• Continuity Check: Audible signal <10Ω, max current 1.5mA
• Sampling Frequency: 3 samples per second
• Auto Power off: After ~5 minutes of inactivity.
• Over Limit: "OL" indicated on display
• Polarity: "-" on display indicates negative polarity
• Display: 3-3/4 digit, 4000 Count LCD
ELECTRICAL SPECIFICATIONS
Function Range Resolution Accuracy
Capacitance
40.00nF 0.01nF ±(4% + 25 digits)
400.0nF 0.1nF
±(4% + 8 digits)
4.000μF 0.001μF
40.00μF 0.01μF
400.0μF 0.1μF
4.000mF 0.001mF ±(10% + 9 digits)
Maximum Input: 600V AC RMS or 600V DC
Temperature
°F
-40° to 103°F
1
°F
±(2.0% + 8 digits)
104° to 931°F
±(1.6% + 5 digits)
932° to 1832°F
±(2.0% + 2 digits)
Temperature
°C
-40° to 40°C
1
°C
±(2.0% + 4 digits)
-41° to 500°C
±(1.5% + 3 digits)
501° to 1000°C
±(1.5% + 2 digits)
Maximum Input: 600V AC RMS or 600V DC
Frequency
10Hz to
60kHz
0.001Hz
to 0.01kHz
±(0.1% + 5 digits)
Duty Cycle
0.1% to 99.9%
10Hz to 10kHz
0.1%
±1.5%
(Range: 10% – 90%)
Maximum Input: 600V AC RMS or 600V DC
Voltage Range: 8V to 220V AC RMS
ENGLISH
WARNINGS
To ensure safe operation and service of the meter, follow these
instructions. Failure to observe these warnings can result in
severe injury or death.
• Before each use verify meter operation by measuring a known
voltage or current.