3
ELECTRICAL SPECIFICATIONS
Function Range Resolution Accuracy
AC Voltage
(V AC)
400.0mV 0.1mV ±(1.8% + 5 digits)
4.000V 0.001V ±(1.5% + 5 digits)
40.00V 0.01V
±(1.2% + 5 digits)
400.0V 0.1V
600V 1V ±(1.5% + 5 digits)
DC Voltage
(V DC)
400.0mV 0.1mV ±(1.0% + 8 digits)
4.000V 0.001V
±(0.8% + 3 digits)40.00V 0.01V
400.0V 0.1V
600V 1V ±(1.0% + 3 digits)
Input Impedance: ~10MΩ
Frequency Range: 45 to 400Hz
Maximum Input: 600V AC RMS or 600V DC
AC Current
(A AC)
40.00A 0.01A
±(2.0% + 9 digits)
400.0A 0.1A
DC Current
(A DC)
40.00A 0.01A
±(2.0% + 9 digits)
400.0A 0.1A
Frequency Range: 50 to 60Hz
Minimum Current Measurable: 0.3A AC or DC
DC
Microamps
(DC µ)
200µA 0.1µA ±(1.0% + 5 digits)
Maximum Input: 600V AC RMS or 600V DC
Resistance
400.0Ω 0.1Ω ±(1.2% + 5 digits)
4.000kΩ 0.001kΩ
±(1.2% + 3 digits)
40.00kΩ 0.01kΩ
400.0kΩ 0.1kΩ
4.000MΩ 0.001MΩ
40.00MΩ 0.01MΩ ±(2.0% + 5 digits)
Maximum Input: 600V AC RMS or 600V DC