ENGLISH
CONTINUITY
1. Insert RED test lead into VΩµA jack
5
, and BLACK test lead
into COM jack
4
, and rotate function selector switch
2
to the
Continuity/Resistance/Capacitance/Diode-Test
setting.
NOTE: The meter defaults to Continuity testing in this mode. Ensure
that the Continuity Testing icon
is visible on the display. If not,
press the "SEL/NCV" button
12
repeatedly until the icon is
shown.
2. Remove power from circuit.
3. Test for continuity by connecting conductor or circuit with test
leads. If resistance is measured less than 10Ω, an audible signal
will sound and display will show a resistance value indicating
continuity. If circuit is open display will show "OL".
DO NOT attempt to measure continuity on a live circuit.
OPERATING INSTRUCTIONS
Red leadBlack lead

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the Klein Tools CL390 and is the answer not in the manual?

Klein Tools CL390 Specifications

General IconGeneral
Product typeDigital multimeter
Product colorBlack, Orange
DC voltage range0 - 600 V
Measuring categoryCAT III 600V
Placement supportedHandheld multimeter
Resolution (AC current)200 µA
Temperature measurement range-40 - 1000 °C
Battery typeAAA
Power sourceBattery
Auto power offYes
Number of batteries supported3
Weight and Dimensions IconWeight and Dimensions
Depth215 mm
Width89 mm
Height38 mm
Weight314 g

Related product manuals