P
paula94Aug 9, 2025
What to do if KOBE Ventilation Hood motors and lights are not working after installation?
- PPatricia RobertsonAug 9, 2025
If, after installation, both the motors and lights on your KOBE Ventilation Hood aren't working, several issues could be the cause. First, ensure that the circuit breaker and the unit's power are turned ON, and use a voltage meter to verify the power supply. Next, check and tighten all wire connections to ensure they are secure. Also, examine the wire continuity from the control panel to the processor board. The motor transformer might be defective, so check both its power input and output, replacing it if necessary. Lastly, the control panel or processor board itself could be defective, requiring replacement.