KOBE Range Hoods
Deluxe Series
RA22 SQB-5 Series
Model No.: RA2230SQB-5 (30”)
RA2236SQB-5 (36”)
INSTALLATION INSTRUCTIONS
AND OPERATION MANUAL

Questions and Answers

  • A
    allenmarthaJul 28, 2025
    What to do if lights are working, but the motor is not on my KOBE Deluxe Ventilation Hood?
    • T
      Timothy PhillipsJul 28, 2025
      If your KOBE Ventilation Hood lights are working but the motor isn't, there are a few potential causes. The control panel or processor board might be defective, requiring replacement. Alternatively, the motor itself could be defective and need replacing. Finally, the capacitor(s) might be defective, in which case they should be replaced.
  • M
    Michael KingAug 2, 2025
    Why is my KOBE Deluxe not venting out correctly?
    • R
      rosalesmartinAug 2, 2025
      If your KOBE Ventilation Hood isn't venting correctly, several factors could be responsible. It could be due to a defective control panel or processor board, which would need to be replaced. The range hood might be installed outside the recommended clearance; adjust it to 26” to 30” from the cooktop (or 30” to 36” for an island hood). Insufficient make-up air in the house can also be a cause; open a window to improve performance. Finally, there might be an obstacle blocking the duct work, so ensure that you remove any obstructions.
  • R
    Raymond RossAug 7, 2025
    How to troubleshoot KOBE Deluxe when both motors and lights are not working after installation?
    • L
      Laura KingAug 7, 2025
      If your KOBE Ventilation Hood isn't working (both motors and lights), here's what to check: * Ensure the circuit breaker and unit's power are ON; use a voltage meter to confirm power supply. * Verify and tighten all wire connections. * Check the wire continuity from the control panel to the processor board.
  • B
    Brenda ChapmanAug 11, 2025
    What to do if the motor is working, but the lights are not working on my KOBE Ventilation Hood?
    • T
      Tammy SpencerAug 12, 2025
      If your KOBE Ventilation Hood motor is working, but the lights aren't, there could be several reasons. The hood might not be secured properly; check the installation and tighten the mounting bracket. The LED light fixture(s) could be defective, requiring replacement. Alternatively, the light wiring(s) might be loose; check the wire continuity from the processor board to the light transformer and then to the LED light fixture(s).
  • D
    Dennis MasonAug 17, 2025
    Why is my KOBE Deluxe vibrating?
    • M
      Melanie BrownAug 17, 2025
      If your KOBE Ventilation Hood is vibrating, it could be due to a few reasons. The control panel or processor board may be defective, and require replacement. The blower system might not be secure; try tightening the turbine impeller/squirrel cage and air chamber. Alternatively, the turbine impeller/squirrel cage could be unbalanced and in need of replacement.
  • L
    Lauren ReynoldsAug 22, 2025
    How to stop cold air coming into the home from KOBE Deluxe Ventilation Hood?
    • R
      Rebekah WellsAug 22, 2025
      If cold air is coming into your home from the KOBE Ventilation Hood, consider these possible causes: * The pipe size might be smaller than recommended; change the ducting to match the manufacturer's suggestions. * The pipe connection may not be properly sealed; check the pipe installation. * The damper might be improperly installed or missing; check the damper installation.

Summary

Important Safety Instructions

General Safety Precautions

General safety measures for installation and operation to prevent fire, electric shock, or injury.

Grease Fire Safety

Specific steps to reduce personal injury risk during a kitchen grease fire.

Components of Package

Installation

Installation Calculation

Instructions for calculating installation dimensions based on table references.

Installation Safety Warning

Important safety advice regarding sharp edges and using electrical screwdrivers during installation.

Operating Instructions

Control Panel and Basic Functions

Overview of the control panel, power, speed, and light controls.

ECO Mode Operation

Detailed guide for activating and managing the ECO Mode for enhanced air quality.

Maintenance

Hood Surface Cleaning

Proper methods for cleaning the hood's exterior surface and finish.

Baffle Filter and Oil Tunnel Cleaning

Steps for cleaning removable filters and oil tunnels, including dishwasher safety.

Specifications

Measurements & Diagrams

Parts List

Circuit Diagram

Trouble Shooting

Warranty

Warranty Certificate Overview

Details on obtaining warranty service and proof of purchase requirements.

Limited Labor and Parts Warranty

Explains the duration and coverage of labor and parts warranties.

Warranty Coverage Details

Defines what is covered and not covered by the warranty.

Warranty Void Conditions

Lists conditions under which the product warranty will be invalidated.

Warranty Information Form

Customer Information for Warranty

Fields to record purchase date, model, and serial number for service.

Warranty Service Contact

Contact details for obtaining warranty service and spare parts.

KOBE Deluxe Series Specifications

General IconGeneral
MaterialStainless Steel
LightingLED
Available Widths30", 36"
Speed Levels3
Filter TypeBaffle Filter