EasyManua.ls Logo

Kohler KD440

Kohler KD440
74 pages
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Loading...
92
90 91
93
9
- 49 -
LUBRICATION SYSTEM
KD 225_315_350_400_440 Workshop Manual_cod. ED0053029330_1° ed_ rev.00
Oil lter
Filtercomponents:KD 315/350
1 Seal
2Adhesive
3Endcap
4 Filteringmaterial
5 Plate
Dimensionmm:A =26.5B=18C=88.5D =67.5E =8.5
Characteristics:
Usefullteringarea=75cm
2
Degreeofltration=50µm.
Theby-passvalveissetat0.6-0.8bar.
Filtercomponents:KD 225
7 Rubberpad
8Uppercover
9Filterelement
10 Lowercover
Dimensionmm:A =19.0-19.3B=12.5C=83.0-83.5
Characteristics:
Usefullteringarea75cm
2
Degreeofltration=40-60µm.
Seepage18forthereplacementfrequencies.
Oil pressure check
Whenassemblyoperationsarecompletedllenginewithoilandfuel;
connecta10barpressuregaugetotheoilltertting.
Starttheengineandcheckpressureasafunctionoftheoiltempera-
ture(seebelow).
Calibrated pipe for lubrication of hydraulic tappets
The pipe is tted to the hydraulic tappets oil line (see g. 83, detail
11).
If the calibrated hole is clogged, the tappets are not sufciently
lubricated,valveclearanceisthereforeincreasedandtheenginemay
benoisier.
Ifthediameterofthecalibratedpipe islargerthantheones givenin
picture93,thepressureexertedby the hydraulic tappetsmaycause
thevalvestoremainopenevenduringthecompressionphase.

Table of Contents