STORAGE
Internal engine protection:
-Starttheengineandallowittoheatup.
-Removethedrainplugandlettheoilowoutcompletely.
-Replacetheoillterwithanewone.
- Clean the oil drain plug and after inserting a new gasket,
tightenit.
- Fill up with oil to the upper level of the dipstick, usingAGIP
RUSTIA C30 (for countries in which this product is not
availablendanequivalentproductonthemarket).
-Starttheengineforabout10minutes,checkforoilleaks,and
thenstoptheengine.
Injection systems protection:
-Emptythefueltank.
-Replacethefuellterwithanewone.
-Fillupwithfuelcontaining10%AGIPRUSTIANT.
-Afterbleedingair,starttheengine,makesuretherearenofuel
leaksandthenstoptheengine.
External engine protection:
- Carefully clean the cylinder cooling system ns and the
ywheelns.
- Protect the external non-painted surfaces withAGIP RUSTIA
68/F.
-Sealtheintakeandexhaustsystemswithadhesivetape.
-Covertheenginewithanylonorplasticsheet.
-Storeinadryplace,preferablynotdirectlyonthegroundand
awayfromhighvoltageelectricitylines.
STORAGE
When the engines are not used for more than 3 months, they must be protected by the measures described
below:
KD 225_315_350_400_440 Workshop Manual_cod. ED0053029330_1° ed_ rev.00