INDICATES:
80>
(Rev 1.3 only)
1. This is an optional mode,
which is not as energy
efficient.
1. Replace jumper to restore
normal energy efficient
minimum-rinse mode.
Machine is in Full-Rinse
Mode. (Left Jumper is pulled,
on Controller)
90>
(Rev 1.3 only)
1. This is a normal condition,
indicating that the Bin is full.
(Bin Probe is cold!)
2. If Code 90 is indicated, but
Bin is not full, check for
faulty Bin Probe, bad wiring
to Bin Probe or faulty
Controller Board.
1. No action required.
2. Repair wiring, replace bin
Probe, or replace
Controller.
Ice Bin Full (A cold Bin
Probe will shut down the
icemaker right after the next
harvest is complete)