EasyManuals Logo

Koldfront WAC25001W Service Manual

Koldfront WAC25001W
31 pages
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Page #24 background imageLoading...
Page #24 background image
23
6.4 Fan-Only Mode
If the temperature can’t be controlled by the selected mode and the room ambient temperature is
shown on the display the unit will default to fan only mode.
The readout can only display a temperature of 32 to 99 (0 to 37.) lf the temperature is out of that
range the display will show LO or HI.
The Timer function works in fan-only mode.
The follow me function (on some models) does not work in fan-only mode.
6.5 Cooling Mode
The cooling temperature can be set from 62 to 86 (17 to 30.)
Sleep, Timer and Energy Saver functions work in cooling mode.
The compressor will run when the difference between the set temperature and the actual ambient
room temperature conforms to the chart below:
When TA≤TS (for 1 minute) the compressor turns off.
When T1>TS+2 the compressor turns on.
(TA-Ts)
+2
0
Operation conditon
compressor off with a delay of 1 minute
compressor on

Other manuals for Koldfront WAC25001W

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the Koldfront WAC25001W and is the answer not in the manual?

Koldfront WAC25001W Specifications

General IconGeneral
Description of productWindow Air Conditioner and Heater
ModelWAC25001W
ColorWhite
Voltage/Frequency208-230V / 60Hz
Current (Cooling / Heating)11.3 / 22.5A
BTUs (Cooling / Heating)25, 000 / 16, 000
CoolantR410A, 36.7 oz.
Timer24 Hour
Weight and Dimensions IconWeight and Dimensions
Dimensions W x D x H26.5” x 26.5” x 18.6”
Weight131 lbs.