6.7 Auto-Defrost Function
The Auto-defrost function operates according to the chart below:
When TE is below 30 the evaporator will frost. As the unit defrosts the indoor fan will continue
to operate.
When the temperature is up over 55 the unit will stop defrosting.
6.8 Sleep Mode
This mode has a duration of 7 hours and can be used in Cool and Dry mode.
In sleep mode the fan speed will default to Auto.
In the first 60 minutes, the set temp will rise 2 (1) each half hour. Then it will keep a steady
temperature for 6 hours until the mode stops.
If you change any settings after sleep mode starts, the function will stop.
TE
55
30
compressor off
when TE is lower than 30
lasting for 5 seconds
compressor on