EasyManua.ls Logo

Komatsu 06253 - Display the Contents of the Record (Protocol) Memory

Komatsu 06253
447 pages
Print Icon
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Loading...
OPERATION 3.4 ELECTRONIC TEXT MONITORING SYSTEM ETM
99
3.4.4 DISPLAY THE CONTENTS OF THE RECORD (PROTOCOL) MEMORY
Display
Example (entry no. 2)
Display:
Press to display Protocol memory.
7
PRO
Last entry of the proto-
col memory will be dis-
played first. Higher
numbers indicating
older entries.
Fault mes-
sage going
PROTOCOL entry no: 1 status: going
message: 2 date 15.07.07 at 15:27:32
Message 2
or
Press until the desired entry no.
(entry No. 2) appears
2
UP
3
DOWN
PROTOCOL entry no: 2 status: coming
message: 2 date 14.07.07 at 16:20:00
Press to display message 2.
1
MESSAGE
$h:......Central lubrication system
fault