©2009 KONICA MINOLTA
www.konicaminolta.eu
Konica Minolta Sensing, Inc. Osaka, Japan
Konica Minolta Sensing Americas, Inc. New Jersey, U.S.A. Phone: 888-473-2656 (in USA),
201-236-4300 (outside USA)
Konica Minolta Sensing Europe B.V. European Headquarter/BENELUX Nieuwegein, Netherland Phone: +31(0)30 248-1193 Fax: +31(0)30 248-1280
German Office München, Germany Phone: +49(0)89 4357 156 0 Fax: +49(0)89 4357 156 99
French Office Roissy CDG, France Phone: +33(0)1 493-82519 Fax: +33(0)1 493-84771
UK Office Milton Keynes, United Kingdom Phone: +44(0)1908 540-622 Fax: +44(0)1908 540-629
Italian Office Milan, Italy Phone: +39 02 39011.425 Fax: +39 02 39011.223
Swiss Office Dietikon, Switzerland Phone: +41(0)43 322-9800 Fax: +41(0)43 322-9809
Nordic Office Västra Frölunda, Sweden Phone: +46(0)31 7099464 Fax: +46(0)31 474945
Belgian Office Zaventem, Belgium Phone: +32 (0)2 7170 933 Fax: +32 (0)2 7170 977
Austrian Office Wien, Austria Phone: +43(0)1 87882-430 Fax: +43(0)1 87882-431
Polish Office Wroclaw, Poland Phone: +48(0)71 33050-01 Fax: +48(0)71 734 52 10
Distribuidor para España y Portugal AQUATEKNICA S.A. Valencia, Spain Phone: +34 963 30 20 13 Fax: +34 963 30 03 96
Konica Minolta (CHINA) Investment Ltd. SE Sales Division Shanghai, China Phone: +86-021-5489 0202 Fax: +86 -021-5489 0005
SE Beijing Office Beijing, China Phone: +86-010-8522 1551 Fax: +86-010-8522 1241
SE Guangzhou Office Guangzhou, China Phone: +86-020-3826 4220 Fax: +86-020-3826 4223
Konica Minolta Sensing Singapore Pte Ltd. Singapore Phone: +65 6563-5533 Fax: +65 6560-9721
Konica Minolta Sensing, Inc. Seoul Office Seoul, Korea Phone: +82(0)2-523-9726 Fax: +82(0)2-523-9729
< System Configuration >
Certificate No: JQA-E-80027
Registration Date:
March 12, 1997
Certificate No: YKA 0937 154
Registration Date:
March 3, 1995
Specications Spectrophotometer CM-5
Illumination/viewing system
Reflectance:
di:8°, de:8° (diffuse illumination: 8° viewing) / SCI (specular component included)/SCE (specular component excluded) switchable
Conforms to CIE No. 15, ISO 7724/1, ASTM E 1164, DIN 5033 Teil 7, and JIS Z 8722 (Condition c)
Transmittance: di:0°, de:0° (diffuse illumination: 0° viewing)
Integrating sphere size
Ø152 mm
Detector
Dual 40-element silicon photodiode arrays
Spectral separation device
Planar diffraction grating
Wavelength range
360 nm to 740 nm
Wavelength pitch
10 nm
Half bandwidth
Approx. 10 nm
Measurement range
0 to 175 % (Reflectance or transmittance); Output/display resolution: 0.01%
Light source
Pulsed Xenon lamp
Measurement time
Approx. 1 s (to data display/output); Minimum measurement interval: Approx. 3 s
Measurement/ illumination area
Reflectance: Changeable by changing mask and settings. LAV: Ø30 mm / Ø36 mm; MAV (optional): Ø8 mm / Ø11 mm; SAV (optional): Ø3 mm / Ø6 mm
Transmittance: Ø20 mm
Repeatability
Spectral reflectance: Standard deviation within 0.1% (400 nm to 740 nm) / Chromaticity value: Standard deviation within ΔE*ab 0.04
* When a white calibration plate is measured 30 times at 10-second intervals after white calibration
Inter-instrument agreement
Within ΔE*ab 0.15 (Typical) I (Based on 12 BCRA Series II color tiles compared to values measured with a master body at 23°C)
Transmittance chamber
No sides (unlimited sample length); Depth (maximum sample thickness): 60 mm
Sample holder (optional) for holding sheet samples or containers of liquid samples can be installed/removed
Display
14.5 cm TFT color LCD
Display languages
English, Japanese, German, French, Italian, Spanish, Simplified Chinese
White calibration
Automatic white calibration (reflectance) / 100% calibration (transmittance) using internal white calibration plate
Interfaces
USB 1.1 (Connection to PC; USB memory stick); RS-232C standard (Connection to serial printer)
Observer
2° Standard Observer or 10° Standard Observer
Illuminant
A, C, D50, D65, F2, F6, F7, F8, F10, F11, F12, ID50, ID65 (simultaneous evaluation with two light sources possible)
Displayed data
Spectral values, spectral graph, colorimetric values, color-difference values, color-difference graph, pass/fail judgment, pseudo color, color assessment
Color space
L*a*b*, L*C*h, Hunter Lab, Yxy, XYZ, Munsell, and color differences in these spaces (except for Munsell)
Index
Reflectance: MI; WI (ASTM E 313-73, ASTM E 313-96); YI (ASTM E 313-73, ASTM E 313-96, ASTM D 1925); ISO Brightness, B (ASTM E 313-73)
Transmittance: Gardner, Iodine, Hazen (APHA), European Pharmacopoeia, US Pharmacopeia
User index
User-defined index
Color-difference equation
ΔE*ab (CIE 1976), ΔE*94 (CIE 1994), ΔE00 (CIE 2000), ΔE (Hunter), CMC (l: c)
Pass/fail judgment
Tolerances can be set to colorimetric values (except Munsell), color-difference values, or reflectance index values
Storable data
Sample data: 4,000 measurements; Target color data: 1,000 measurements
USB memory stick storage
Storage of measurement data and target color data. Storage/reading of measurement condition settings (Security-en-abled USB memory sticks cannot be used.)
Power
AC 100 to 240 V, 50/60 Hz (using exclusive AC adapter)
Size
Slide cover closed: 385 (W) × 192 (H) × 261 (D) mm I Slide cover open: 475 (W) × 192 (H) × 261 (D) mm
Weight
Approx. 5.8 kg
Operating temperature/humidity range
13 to 33°C, relative humidity 80 % or less (at 35°C) with no condensation
Storage temperature/humidity range
0 to 40°C, relative humidity 80 % or less (at 35°C) with no condensation
Standard
accessories
Optional
accessories
Spectrophotometer
CM-5
Target Mask (Ø3 mm)
CM-A195
Petri Dish Measurement
Set
Target Mask (Ø8 mm)
CM-A196
Target Mask (Ø30 mm)
CM-A197
Transmittance Mask
CM-A200
(Ø20 mm)
Dust Cover
CM-A191
CM-S100w
Cell
CM-A98
(10 mm)
Cell
CM-A97
(2 mm)
Cell
CM-A99
(20 mm)
Plastic Cell
CM-A132
(20 mm; 100 pcs.)
Specimen Viewing Mirror
CM-A202
Connecting Cable CM-A58
USB Cable (2 m) IF-A19
AC Adapter
Plastic Cell
CM-A131
(10 mm; 100 pcs.)
Plastic Cell
CM-A130
(2 mm; 100 pcs.)
Personal computer
(Commercial product)
Data printer
(Commercial product)
CM-A205
Transmittance
Measurement Set
White Calibration Plate CM-A210
(with CD-ROM containing calibration data and data-setting software)
Zero Calibration Box CM-A124
Target Mask (for Petri Dish) CM-A203
Petri Dish CM-A128
Calibration Glass (for Petri Dish)
CM-A212
Accessory Case CM-A193
CM-A206
Transmittance Zero Calibration Plate
CM-A213
Transmittance Specimen Holder
CM-A96
Transmittance Specimen Holder
Attachment
CM-A199
Accessory Case CM-A193
10 mm Cell
Measurement Set
10 mm-wide cell
(Commercial product)
CM-A207
Transmittance Specimen
Holder (10 mm)
CM-A198
Transmittance Zero Calibration
Plate (10 mm)
CM-A204
SAFETY PRECAUTIONS
For correct use and for your safety, be sure to read the instruction manual before using
the instrument.
Always connect the instrument to the specified power
supply voltage. Improper connection may cause a fire
or electric shock.
Be sure to use the specified batteries. Using improper
batteries may cause a fire or electric shock.
- Specifications and appearance subject to change without notice.
- Company names and product names herein are trademarks or registered trade-
marks of their respective companies.
- The specifications and drawings given here are subject to change without prior
notice.
- If you have any questions about specifications, please contact your Konica Minolta
representative.