19
Changingbetweenresponderand
transpondermode
Thetranspondercanalsobeusedasaresponderunit.
Prerequisites
Thetranspondermustbechargedbeforeuse.
BydefaultwhenthecNODEMiniSisturnedonitisintranspondermode.
Thesignalinputfortheresponderfunctionmustbebetween2and6mswithapositive
pulseof5to24V .
Procedure
1Whenrespondertriggersignalsarereceived,themodeisautomaticallychanged
toresponder.
2Oncetherespondertriggersignalsstop,itwilltake1minutebeforethecNODE
MiniSchangesautomaticallybacktotranspondermode.
TurningontheTTC
UsetheTransponderTestandCongurationunittocheckthatthetransponderisready
foruse.
Procedure
1Placetheunitinasuitablelocation.
2Openthecasebypressingthehandleknobsandpullingthehandlesup.
3Turnonthemainpowerswitchtoloadthesoftware(thistakesapproximately1.5
minutes).
Result
Thesystemisnowreadyforoperation.
Acoustictest
Performtheacoustictesttomakesurethetransponderisfunctioning.
Prerequisites
Pre-deploymentcheckshavebeendone.
Gettingstarted