ETX-DC®/ Specifications
9
Mode
[A] 5V
[A] 5VSB
[W]
Full Load
2,42
0,07
12,43
Idle
1,87
0,04
9,53
Idle with C1E/EIST
1,78
0,04
9,11
Standby S1
1,41
0,03
7,18
Standby S3
0,00
0,235
1,18
Soft Off S5
-
0,29
1,44
3.6 Environmental Specifications
Temperature
Operating: (with Kontron Embedded Modules GmbH heat-spreader plate assembly):
» Ambient temperature: 0 to +60 °C
» Maximum heatspreader-plate temperature: 0 to +60 °C (*)
» Non-operating: -30 to +85 °C
Note: *The maximum operating temperature with the heatspreader plate is the maximum measurable temperature
on any spot on the heatspreader’s surface. You must maintain the temperature according to the above
specification.
Operating (without Kontron Embedded Modules GmbH heat-spreader plate assembly):
» Maximum operating temperature: 0 to +60 °C (**)
» Non operating: -30 to +85 °C
Note: **The maximum operating temperature is the maximum measurable temperature on any spot on a module’s
surface. You must maintain the temperature according to the above specification.
Humidity
» Operating: 10% to 90% (non condensing)
» Non operating: 5% to 95% (non condensing)