126 Part Number STH063 9/17

NOTE: These characteristics may vary depending on
operating conditions.
Cycle Times
Freeze Time + Harvest Time = Total Cycle Time
Air Temp.
Around Ice
Machine

Freeze Time Harvest
Time

  
 11.0-11.9 11.6-12.5 13.4-14.4
1.0-2.5
 11.2-12.0 11.5-12.4 13.5-14.6
 11.4-12.3 13.0-14.0 13.6-14.7
 11.6-12.5 13.3-14.3 13.9-14.9
 11.7-12.6 13.5-14.6 14.1-15.2
Times in minutes
24 Hour Ice Production
Air Temp.
Around Ice


  
 835 800 700
 825 805 695
 810 720 690
 800 705 680
 790 695 670
Based on average ice slab weight of 7.25 – 7.75 lb (3.3 – 3.5 kg)
Water regulating valve set to maintain 300 PSI discharge pressure.
Condenser Water usage per 100 lbs ice = 131 gal (45 kg = 496 L)
230/50/1 production is approximately 12% lower than 230/60/1.
Operating Pressures
Air Temp.
Around Ice
Machine

Freeze Cycle Harvest Cycle
Discharge
Pressure
PSIG
Suction
Pressure
PSIG
Discharge
Pressure
PSIG
Suction
Pressure
PSIG
 290-305 64-36 150-165 100-125
 290-305 64-36 150-165 100-125
 290-310 68-37 155-175 100-125
 295-335 72-39 160-180 110-125
 305-335 73-41 160-180 110-130
 310-345 74-44 165-185 115-130
Suction pressure drops gradually throughout the freeze cycle