42 Part Number STH063 9/17
Preventative Maintenance Cleaning
This cleaning procedure can be performed between the bi-
annual cleaning and sanitizing cycles. This procedure does
not require removing the ice from the bin.
Step 1 Place the toggle switch in the off position after
ice falls from the evaporator at the end of a Harvest cycle.
Or, place the toggle switch in the off position and allow the
ice to melt off the evaporator.
,
Caution
Never use anything to force ice from the evaporator.
Damage may result.
n
Warning
Wear rubber gloves and safety goggles (and/or face
shield) when handling Ice Machine Cleaner or Sanitizer.
Step 2 To start a cleaning cycle, place the toggle switch
in the clean position. Water will flow through the water
dump valve and down the drain. Wait until the water
trough refills, then add the proper amount of ice machine
cleaner to the water trough.
Model Amount of Cleaner
KT0300 - KT0400 - KT0420
KT0500 - KT0700 - KT1000
5 ounces (150 ml)
KT1700 9 ounces (265 ml)
Step 3 Wait until the clean cycle is complete
(approximately 24 minutes) then place the toggle switch in
the off position.