Part Number STH063 9/17 17
Ice Machine Heat of Rejection
Series
Ice Machine
Heat of Rejection
1
Air Conditioning
2
Peak
KT0300 4600 5450
KT0400 3800 6000
KT0420 5400 6300
KT0500 5300 6100
KT0700 9000 13900
KT1000 17000 20700
KT1700 24700 29000
1 B.T.U./Hour
2 Because the heat of rejection varies during the ice making cycle,
the figure shown is an average.
Ice machines, like other refrigeration equipment, reject heat
through the condenser. It is helpful to know the amount of
heat rejected by the ice machine when sizing air conditioning
equipment where self-contained air-cooled ice machines are
installed.
Leveling the Ice Machine
1. The leveling legs must be screwed into the bottom of
the bin as far as possible.
,
Caution
The legs must be screwed in tightly to prevent them
from bending.
2. Move the bin into its final position.
3. Use a level on top of the bin. Adjust each foot as
necessary and level from front to back and side to
side.