If the harvest float switch hasn’t opened for 10 continuous
seconds within 4 minutes of the water inlet valve
energizing, the ice machine stops.
Safety Limit 3 is bypassed on the initial cycle (manual
start or after a full bin/safety limit condition). For
all subsequent cycles, the ice machine stops for 30
minutes when the water inlet valve is energized for
4 minutes and the harvest float valve didn’t open.
Control board lights SL#1 and SL#2 will flash on/off at 1
second intervals.
The ice machine automatically restarts at the end of
the 30 minute delay period and stops flashing the
control board lights.
If 100 consecutive failures occur, the ice machine stops
and the SL#1 & SL#2 lights flash on/off at 1 second
intervals.
SL#1 & SL#2 will flash 3 times on start-up and
automatically erase after 100 normal cycles.