8.4 Exhaust Vent Requirements
Venting a KOZI pellet burner for a mobile home is similar to that of a conventional
home. Please refer to the “Typical Mobile Home Installation Configuration” section for
typical venting configurations the “Venting System” for vent termination and other
requirements. It is highly recommended that 3 ft. minimum of vertical venting be used
(as shown in Figure 15A and Figure 15B). This will reduce the chance of smoke spillage
into the mobile home in case of a power failure.
8.5 Other Mobile Home Installation Requirements
1. The heater must be securely anchored to the floor of the mobile home.
There are 2 holes located on the base of the stove near the back (4 on
KSH models). Use two 1/4” lag bolts (not supplied) in these holes to
anchor the stove to the floor of the mobile home. For KSH models, the
side panels will need to be opened to access these holes.
2. There must be a noncombustible floor protector placed underneath the
heater and extending a minimum of 6” (150 mm) in front of the heater
(see “Clearance to Combustibles” section for more information).
3. This heater can not be installed in any sleeping room of the mobile home.
4. The heater must be grounded to the steel chassis of the mobile home
(unless this is not required by local code).
5. The installation must be in accordance with the Manufactured Home and
Safety Standard (HUD), CFR 3280, Part 24
CAUTION: THE STRUCTURAL INTEGRITY OF THE FLOOR, WALL AND
ROOF OF THE MOBILE HOME MUST BE MAINTAINED.
WARNING: DO NOT INSTALL IN A BEDROOM OF A MOBILE HOME