Page 7
Figure 4. Insert Clearances
Table 1. Clearance Dimensions
Additional installation information can be found in the “Typical Installation Configura-
tions” section and your venting manufacturer/supplier’s literature.
INSTALLATION COMMENT: We recommend sufficient space be provided (mini-
mum 20 inches/500 mm) on each side of the heater to service the equipment area. If this
is not possible, a provision must be made to pull the heater out for service.
Dimension Description BayWin Model 100 KSH Series BayWin Insert
Model 100
Insert
A
Unit to side wall or side
facin
12" (300 mm) 12" (300 mm) 5" (125 mm)
B Unit to back wall
C Corner of unit to wall
D Alcove height
E Overall unit height 30.5" (775 mm)*
F Alcove depth (Maximum)
G Alcove width 48" (1220 mm)
H
Floor to centerline air
intake
3" (75 mm)
J Floor to centerline exhaust 10" (255 mm)
K Unit to mantle
L Unit to top facing
N/A
13" (330 mm)
13" (330 mm)
38" (965 mm)
8.5" (215 mm)
11" (280 mm)
18" (458 mm)
All dimentions are minimum dimentions unless marked.
N/A
N/A
5" (125 mm)
1" (25 mm)
1" (25 mm)
48" (1220 mm)
34" (865 mm)
* Overall unit height with 200lbs hopper extension is 39" (990 mm).
* Overall unit height with 280 lbs hopper extension is 47" (1195 mm).
30.5" (775 mm) 21.25" (540 mm)
N/A
30" (760 mm)
48" (1220 mm)
1.5" (38 mm)
INSTALL VENT AT CLEARANCES SPECIFIED BY
THE VENT MANUFACTURER