12 Servicing
12.4 Replacing the mechanical seal (inner bearing)
2. Ensure that the fixing screw11 of the pump-side coupling half10 is loosened.
3. Slide the pump-side coupling half onto the shaft until it stops and tighten the fixing screw.
4. Tighten the socket screws9 between the pump2 and pump bracket3 with torque.
5. Measure and write down the distanceX between the face of the coupling claws and the fitting
surface of the pump bracket.
6. Ensure that the fixing screw6 of the motor-side coupling half5 is loosened.
7. Slide the motor-side coupling half onto the shaft end of the motor7.
8. Check the distance between the face of the coupling teeth pump-side and the fitting surface of
the motor flange. The distance has to be adjusted to the measured valueX minus coupling dis-
tanceE, see table of limit values for aligning the shaft coupling Ä Connection,Page20.
9. Tighten the fixing screw on the motor-side coupling half and insert the coupling intermediate
ring4.
10. Secure the motor with eye bolts/hoisting equipment so that the motor can be pushed exactly hori-
zontally into the pump bracket and the coupling halves interlock.
11. Tighten the socket screws1 between the motor and pump bracket with torque.
12.4 Replacing the mechanical seal (inner bearing)
12.4.1 Removing the mechanical seal
Personnel qualification: o Fitter
Personal protective equipment: o Work clothing
o Protective gloves
o Safety boots
Aids: o Plastic hammer
o Extractor
Requirement:
ü Coupling removed
32
OIC 18en-GB Edition 2020-01
Operating instructions