8 Installation, removal
8.5 Installing the heating system (optional)
3. Remove the lower screw plug8 of the heating duct6 at the station block (figure shows the large
pump station).
4. Insert the heating element from below into the heating duct6 and tighten the screw plug of the
heating element4.
5. Large pump station: Prepare the second heating element in the same manner and insert it into
the second heating duct.
6. Remove the upper screw plug7 of the heating duct at the station block.
7. Small pump station: Fill the heating duct up to a maximum of 45 mm under the threaded end of
the screw plug with thermal oil.
-or-
Large pump station: Fill both heating ducts up to a maximum of 70 mm under the threaded end
of the screw plug with thermal oil.
8. Close the heating duct again with the upper screw plug7.
24
OID 02en-GB Edition 2019-11
Operating instructions