8 Installation, removal
8.6 Removing the pump station
8.5.3 Installing the fluid heating system
Personnel qualification: o Fitter
Personal protective equipment: o Work clothing
o Protective gloves
o Safety boots
1. Remove the upper and lower screw plug of the heating duct.
1 2
2. Small pump station: Mount the piping2 with the inserted screw connection1.
1 2
33
3. Large pump station: Mount the piping2 with the inserted screw connection1 and the swivel in-
serted screw connection3.
8.5.4 Installing the heating system special design
When installing special designs contact the manufacturer.
8.6 Removing the pump station
Personnel qualification: o Transport personnel
o Fitter
o Electrician
Personal protective equipment: o Work clothing
o Protective helmet
o Protective gloves
o Safety boots
Aids: o Mobile crane, forklift, hoisting equipment
o Collection tank
DANGER
Risk of death resulting from electric shock.
Ensure that the electrical power supply is de-energized and is secured against being switched
back on.
Observe the operating instructions of the electrical components.
Operating instructions
OID 02en-GB Edition 2019-11