Loading...
10 Operation
10.4 Decommissioning
Fig.23: Stellungen Zweiwegeventil
Notice The two-way valve can be operated during operation.
1. Turn the lever1 to the right.
ð The left-hand connection is connected to the pump station.
2. Turn the lever1 to the left.
ð The right-hand connection is connected to the pump station.
10.3.5 Switching off the pump station
Personnel qualification: o Trained personnel
ATTENTION
Damage to seal through pressurizing during standstill.
Ensure that the maximum permissible system pressure is not exceeded.
1. Switch off the motors.
2. Close the pressure- and suction-side shut-off devices.
10.4 Decommissioning
10.4.1 Taking the pump station out of operation
Personnel qualification: o Fitter
o Electrician
Personal protective equipment: o Work clothing
o Protective gloves
o Safety boots
o Face protection
Aids: o Collection tank
WARNING
Risk of injury through emitted pumped liquid.
Pumped liquids can be hot, poisonous, combustible and caustic.
Wear personal protective clothing during all the work. Ensure face protection.
Collect any discharging pumped liquid safely and dispose of it in an environmentally compatible
manner in accordance with the applicable local regulations.