10 Operation
10.2 Commissioning
DANGER
Risk of death through emitted pumped liquid.
Pumped liquids can be hot, poisonous, combustible and caustic and can spray out under high pres-
sure.
► Observe the operating instructions of the pump.
► Wear personal protective clothing during all the work. Ensure face protection.
► Collect any discharging pumped liquid safely and dispose of it in an environmentally compatible
manner in accordance with the applicable local regulations.
1. Ensure that the lever of the reversing valve4 is in the middle position.
2. Open both screw plugs of the vent holes3 by a max. of 2 rotations so that air can escape during
the filling process.
3. Open the suction-side or pressure-side shut-off device and fill the pump station via the suction
connection1 or pressure connection2.
4. Vent the pumps. Take the corresponding operating instructions of the pumps into consideration in
the process.
5. Tighten both screw plugs of the vent holes3 again.
Filling and venting the pump station via the strainers
Personnel qualification: o Fitter
Personal protective equipment: o Work clothing
o Protective gloves
o Protective helmet
o Safety boots
o Face protection
Aids: o Collection tank
WARNING
Risk of injury through emitted pumped liquid.
Pumped liquids can be hot, poisonous, combustible and caustic.
► Wear personal protective clothing during all the work. Ensure face protection.
► Collect any discharging pumped liquid safely and dispose of it in an environmentally compatible
manner in accordance with the applicable local regulations.
Operating instructions
OID 02en-GB Edition 2019-11
31