Table 3: Machine # DIP-Switch Settings
Machine #
DIP-SWITCH
1 2 3 4
1 (Single or
master unit
1
OFF
ON )
OFF
OFF
OFF
OFF
OFF
OFF
2 OFF ON OFF OFF
3 ON ON OFF OFF
4 OFF OFF ON OFF
5 ON OFF ON OFF
6 OFF ON ON OFF
7 ON ON ON OFF
8 OFF OFF OFF ON
9 ON OFF OFF ON
10 OFF ON OFF ON
11 ON ON OFF ON
12 OFF OFF ON ON
13 ON OFF ON ON
14 OFF ON ON ON
15 ON ON ON ON
Note: After changing the address, the device must be reset by turning OFF
and ON.
6.4.2 Setting the DIP-Switches
When controlling a unit via the RS-232 or RS-485 ports set the
DIP-switches on the rear of the unit.
Figure 5 and Table 4 define the
DIP-switches
2
:
Figure 5: DIP-Switch Settings
Table 4: DIP-Switch Settings
RS-485 Term RS-485 line termination OFF for no RS-485 line termination
ON for RS-485 120Ω line termination
PROG Firmware update Set ON only to update device firmware
MACH # 1, 2, 3, 4 Self Address Sets the MACHINE # (see section 6.4.1)
1 A single or master unit can have the address 0 or 1
2 The default address is 0 (all DIP-switches are OFF)