Electrical connection
The machine is supplied with an electrical power cable with plug. The mains plug must
be fitted to a standard grounded socket with a 30mA residual current operated device.
The socket must be protected with a 16A delay action fuse on the mains side. When
using an extension cable, this must have an earthed lead which is properly connected to
the socket. The conductors in the extension cable must have a minimum cross section of
1.5 mm². Plug connections must be of a spray-proof design, and may not be located on
a wet floor. With extension cables of more than 10 m the minimum cross section must be
2.5 mm! When using a cable drum, always keep the cable wound as far as possible.
Check the line fusing and have the voltage and the available
current intensity checked by an expert in case of uncertainty.
11
Connected load:
Kränzle Profi 160 TS T: 230 V ~, 50 Hz
Kränzle Profi 195 TS T: 230 V ~, 50 Hz
Kränzle Profi 175 TS T: 400 V 3~, 50 Hz
Kränzle Profi 15/120 TS T: 400 V 3~, 50 Hz
If there are too many collectors in your
proximity connected to the network at the
same time, the available voltage and the
current intensity may decline. Consequent-
ly the motor of the high-pressure cleaner
does not start or even blows.
Insufficient quantity of electricity
The power supply may also be insufficient
if the power cable is too long or too thin. If extension cables are too long, this may lead
to a voltage drop causing malfunctions or start-up difficulties.