Setting up – Location
Neither set up or operate the machine in rooms where
there is a risk of fire or explosion nor put it into puddles.
Do not use the machine under water.
14
Putting into operation
4. Put up machine. Release fixing screw
from hexagonal base of hose drum, put
tiltable handle onto the hexagonal base
and fix with screw.
2. Check water inlet filter for
cleanliness prior to putting the
machine into operation!
Manually unscrew hose attachment.
Take out the serial water inlet filter
using needle nose pliers and clean if
filter is soiled
.
1. Move high-pressure cleaner to the job
site. The Kränzle Professionals are movable
machines with sturdy trolleys ideally suited for
difficult terrain and stairs .
3. Each time check oil level at oil-level
glass prior to putting HP cleaner into
operation. (Take care that cleaner is in
horizontal position!)
The oil level must be visible in the oil-level
glass
.