EasyManua.ls Logo

KROHNE AF-E 400 - Pressure Equipment Directive (PED); Applications; 5 Installation

KROHNE AF-E 400
Print Icon
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Loading...
5
UK
4.1 Pressure Equipment Directive (PED)
The units comply with the Pressure Equipment Directive and are designed and
manufactured for group 2 fluids according to the sound engineering practice.
Use of group 1 fluids on request.
4.2 Applications
Conductive liquids with the following properties:
• Conductivity: 20 μS/cm
Viscosity: < 70 mm
2
/s at 40 °C; < 70 cSt at 104 °F
This is a class A product. This product may cause radio interference in
domestic areas.
If required, take appropriate EMC screening measures.
5 Installation
CAUTION!
If the medium temperature is above 50 °C (122 °F) parts of the
housing can increase in temperature to over 65 °C (149 °F).
> Risk of burns.
Protect the housing against contact with flammable substances
and unintentional contact.
Apply the supplied warning label to the sensor cable.
Ensure that the system is free of pressure during installation.
Ensure that no media can leak at the mounting location during
installation.
The unit can be installed independently of the orientation if the following is
ensured:
- No air bubbles can form in the pipe system.
- The pipes are always completely filled.
Calming sections on the sensor's inlet or outlet side are not necessary.

Other manuals for KROHNE AF-E 400