Installation and Operating Instructions OPTIMASS
27
1.3.8 Technical Data
Nominal Flow Rates
01 03 04
Kg/h
15 100 350
Lbs/min
0.5 3.5 12.5
Maximum flow rate
Typically 130 % of the nominal flow rate for the sensor size depending on application.
Minimum flow rate
Depending on measuring error required.
Tube materials:
S 316L
Hastelloy C22
The meter size has a prefix S or H indicating the tube material.
Secondary pressure containment
All OPTIMASS 3000 (7100) Series meters have secondary containment rated to 30 bar or 435 psi.
Materials of construction
Connections: SS 316 L or HC22
Secondary Containment: SS 316 L
Front end housing and post: SS 316 L
Converter housing: Epoxy coated aluminium

Table of Contents