Installation and Operating Instructions OPTIMASS
5
Unpacking the meter
When unpacking your meter, please ensure that no visible damage has occurred during
transportation. If damage has occurred, please contact the carrier for claims.
Your high quality instrument has been fully tested and checked before shipping. The following
items should be included with your instrument unless otherwise requested:
1. Mass Flow Meter OPTIMASS
2. Separate Converter with remote converter wall mount (not for compact version)
3. CD-ROM & Quick Start Guides
4. Spanner to open the electronic housing lids
5. Bar magnet for programming the meter
6. Screw driver for terminal connections
7. Calibration certificate
8. Factory and Material certification, if ordered.
If any of these items are missing, please contact your nearest KROHNE Office or representative
(see back page).
Attention:
Please read the Handbook before installing the meter.
Many problems are avoided when the simple guidelines in this handbook are followed.

Table of Contents

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the KROHNE OPTIMASS Series and is the answer not in the manual?

KROHNE OPTIMASS Series Specifications

General IconGeneral
Housing MaterialAluminum, stainless steel
Measurement PrincipleCoriolis
Flow MeasurementMass flow, density, temperature
Accuracy±0.1% of rate
Repeatability±0.05% of rate
Pressure RangeUp to 400 bar
Communication ProtocolsHART, PROFIBUS DP/PA, Modbus, Foundation Fieldbus
MaterialsStainless steel, Hastelloy
ApprovalsATEX, IECEx
Output Signals4-20 mA, pulse, frequency
Protection ClassIP67
Process ConnectionFlanged, threaded, sanitary
Power Supply24 V DC, 100-240 V AC