MAL-OPS-0969 Version 2.2 15
8. Detector Specification
Gamma and Neutron detection
Gamma sensitivity for Cs137
5 cps/μR/h (500 cps/μSv/h)
Photo peak 1.2 cps/μR/h (120 cps/μSv/h)
Maximum throughput for
gamma channel
2.0 mR/h (20 μSv/h) at 662 keV (spectroscopic) 100 R/h (1
Sv/h) at 662 keV with high dose module
Neutron detector material
9 Cps in a 1 neutron per cm
2
field
Neutron detector gamma
rejection
Better than 10
-7
, meets ANSI N42.34 section 6.7
Maximum throughput for
neutron channel
Operational temperature range
−20°C to +50°C, meets ANSI N42.32 section 7.1, 7.2, 7.5
Device size (excluding phone)
4.8” x 3.1” x 0.9” (122mm x 80mm x 23mm)
Device volume (excluding
phone)
Up to 93% RH ANSI N42.32 section 7.3
Moisture/ dust protection
IP65 as per ANSI N42.32 section 7.4
Monochrome 128x64 OLED Display
Charging via USB or inductive charging
GPS on Android Smartphone, GPS-denied tracking on D3M